MODEL iQ6
Page 4
4. Remove wiring cover.
5. Connect power cable to wiring box using proper connector.
Connect Black to Black (hot), White to White (neutral) and
Green or Bare wire (ground) under second ground screw.
Replace wiring cover.
6. Run 8” round steel duct to installation location.
7. Connect duct to damper. Seal using duct tape to make all
joints secure and air tight.
BLACK TO BLACK
WHITE TO WHITE
GROUND WIRE
TO GROUND
SCREW
ROUGH-IN PLATE
8. Install the calibration button assembly using (2) screws
(provided).
INTERNAL BLOWER DUCTED UNITS ONLY
After the hood is installed and wired, engage the calibration
process (our Guaranteed Performance System Technology to
ensure full-rated airflow is being delivered). Prior to calibration,
ensure that all filters, light bulbs and duct system are installed.
CALIBRATION PROCESS
Hold the calibration button for 3 seconds; calibration button
will light up and stay on for up to 13 minutes. The blower will
start and begin the calibration process. When calibration is
complete, one of two things will occur:
1. The blower turns off and calibration button light stays on =
Successful calibration. Press the button to turn off the LED.
Note: The LED will also turn off if you select any blower
speed on the control.
2. The blower turns off and calibration button light blinks
continuously = Too much restriction in the ductwork is
preventing the IQ Blower System™ from achieving the rated
airflow. The blower is automatically set to maximum intensity.
NOTE: Common items that cause restrictions: restricted
damper flap (backdraft damper, wall cap, roof cap), too
many elbows, duct size less than 80% of hood outlet, poor
transition, use of flex ducting and/or crushed ducting.
Three options are available if your hood system has too
much restriction:
1. Accept airflow as is.
a. Press the calibration button to accept airflow as is. The
IQ Blower System™ is now configured to the highest
possible performance. The blinking calibration light
goes out. Note: The LED will also turn off if you select
any blower speed on the control.
2. Correct duct restriction, clear the original calibration data,
and repeat the calibration process.
a. Correct the duct restriction.
b. Clear the original calibration data by holding calibration
button for 10 seconds. The light will blink 3 times to
confirm and the blower configuration will go back to
default settings.
c. Repeat calibration process from the beginning.
3. Clear calibration data to reset hood to default factory
setting and achieve standard high pressure blower
performance.
a. Clear calibration data and reset hood to factory default
setting by holding calibration button for 10 seconds.
The light will blink 3 times to confirm and the blower
configuration will go back to default settings.
CALIBRATE iQ BLOWER
SYSTEM
CALIBRATION BUTTON
ASSEMBLY
(2) SCREWS
9. Plug blower power cord and rough in plate power cord into
hood receptacles
10. Wrap excess wires with wire ties (provided) to prevent
contact with blower wheel.